Chief Appraiser Says
Reading the actual guideline text below — never a general AI guess
Here's what the passages say about garage dividing walls: A dividing wall is the physical barrier that separates a garage from the rest of a house (or separates different areas within a garage), and whether one exists changes how an appraiser reports the space—if there's no dividing wall, the detached garage is reported only in the Vehicle Storage section and does not need to be listed as a separate outbuilding. The dividing wall also matters for fire safety: the material, thickness, and fire rating of that wall, combined with a solid-core or fire-rated door between the garage and house, form part of a larger fire-separation system that appraisers and inspectors look at together, especially in converted garages where deficiencies in any one component (the wall, the door, or attic access) should be flagged as correctable repair items.
Straight from UAD 3.6 / URAR (FNMA) and Garage Conversions & Attic Stairs (IRC R302.6 fire separation; FHA/VA guidance) — nothing added.
AI Search
General web information, outside Chief Appraiser’s vetted library — verify against the authoritative source before relying on it professionally
Searching the wider web…
© Copyright Notice: © Fannie Mae. UAD 3.6 / URAR reference materials shown for research and reference only. Full documents available at fanniemae.com/uad. Reproduction restricted per Fannie Mae copyright policy.
Chief Appraiser Picks · Related Video
Rules for the house / garage fire separation wall (it's not a firewall) — Structure Tech
0.262
Appendix 4: Detached Garage Examples Appendix F-1: URAR Reference Guide Page 374 of 375 Version 1.3 Example 5: Oversized Detached Garage (No Dividing Wall) In this example, the…
UAD 3.6 / URAR (FNMA) · Appendix F-1 URAR Reference Guide v1.3.pdf · Page 374
· View at official source (fanniemae.com/uad) →
Appendix 4: Detached Garage Examples Appendix F-1: URAR Reference Guide Page 374 of 375 Version 1.3 Example 5: Oversized Detached Garage (No Dividing Wall) In this example, the subject has a 500 sq. ft. detached garage that includes 100 sq. ft. of extra unfinished area with no separation of the area. No Outbuilding Section When the detached garage has no dividing wall, it does not have to be reported as an outbuilding. In this example, no outbuilding was reported, so the Outbuilding section does not display. Vehicle Storage When the detached garage has no dividing wall, it is reported in the Vehicle Storage section only. • In this example, the 500 sq. ft. detached garage is reported. Sales Comparison Approach In this example, Comparable #1 has a 400 sq. ft. detached garage with no additional area, and no outbuildings. Vehicle Storage Subsection Information about the subject property’s garage area populates from the Vehicle Storage section. If the subject or comparable(s) have additional features that impact value and/or marketability, dynamic rows are utilized to support adjustments and conclusions. In this example, any adjustment would be made for the differences in garage area. No Outbuilding Subsection In this example, the subject and all comparables do not have outbuildings, so the Outbuilding subsection does not display.
0.229
Appendix 4: Detached Garage Examples Appendix F-1: URAR Reference Guide Page 362 of 375 Version 1.3 Appendix 4: Detached Garage Examples This appendix shows examples of detached…
UAD 3.6 / URAR (FNMA) · Appendix F-1 URAR Reference Guide v1.3.pdf · Page 362
· View at official source (fanniemae.com/uad) →
Appendix 4: Detached Garage Examples Appendix F-1: URAR Reference Guide Page 362 of 375 Version 1.3 Appendix 4: Detached Garage Examples This appendix shows examples of detached garages and how they are reported in different sections of the URAR. Applicable URAR sections for each example are summarized in this table. Note: Only the portions of Unit Interior and Sales Comparison Approach that address area and rooms are included in these examples. The entire Unit Interior section displays for the ADU, as does the ADU Interior Quality and Condition subsection of the Sales Comparison Approach. Detached Garage Examples Example (Subject Property) Outbuilding (Subject Property) Unit Interior Vehicle Storage Sales Comparison Example (Comp #1) Relevant Sales Comparison Approach Subsections Cost Approach Subsection for Detached Garage 1 Detached garage – vehicle storage only • Garage is heated. √ • Heated detached garage with half bath • Additional outbuilding: Greenhouse • Vehicle Storage • Outbuilding As Is Value of Site Improvements 2 Detached garage with additional separate area (no ADU) • Has dividing wall. • Garage is heated. Workshop/ Garage √ • Detached garage with additional unfinished area (outbuilding: Shed/Garage) • Garage is not heated. • Vehicle Storage • Outbuilding Depreciated Cost - Outbuilding 3 Detached garage with ADU (no additional separate area) • Has dividing wall. • Garage is not heated. • ADU has heat and air conditioning. ADU/Garage For the ADU √ • Heated detached garage with no additional separate area • No outbuildings • Below grade ADU in primary dwelling • Unit(s) for the ADU • Vehicle Storage Depreciated Cost - Outbuilding 4 Workshop with ADU and vehicle storage • Has dividing walls. • Workshop and garage are not heated. • ADU has heat and air conditioning. ADU/ Workshop/ Garage For the ADU √ • Heated detached garage with no additional separate area • No outbuildings • Below grade ADU in primary dwelling • Unit(s) for the ADU • Vehicle Storage • Outbuilding Depreciated Cost – Outbuilding 5 Oversized detached garage (no dividing wall) √ • Detached garage with no extra area • No outbuildings • Vehicle Storage As Is Value of Site Improvements
0.167
which is a visually verifiable item, unlike the harder value question. Where a property's situation looks genuinely ambiguous on the value or permit question, the honest answer is…
Garage Conversions & Attic Stairs (IRC R302.6 fire separation; FHA/VA guidance) · Garage_Conversions_and_Attic_Stairs.txt · Page 4
which is a visually verifiable item, unlike the harder value question. Where a property's situation looks genuinely ambiguous on the value or permit question, the honest answer is that this calls for a licensed appraiser's case-by-case judgment rather than a confident yes-or-no answer from a general reference, and setting that expectation with a seller up front tends to avoid surprises later in the transaction. How this connects to related fire-separation topics already covered. This topic is closely related to, but distinct from, the garage dividing wall and garage attic access items already covered elsewhere in this library. The dividing wall material and fire rating between a garage and the house, the presence of a self-closing solid-core or fire-rated door between them, and a compliant means of attic access are all part of the same underlying fire-separation system, and a deficiency in any one of them can be flagged the same way an appraiser or inspector would flag a missing water heater strap or a missing smoke detector: as a specific, correctable repair item rather than an abstract code violation. Where more than one of these items is deficient at the same time, such as a converted garage with both a non-rated stair and a hollow interior door, it is worth treating the whole fire-separation system as needing attention together rather than addressing one item and assuming the rest is fine, since these systems are typically installed and inspected as a set during original construction and tend to degrade or get modified together during later remodeling work such as a garage conversion. Practical checklist. Check whether a drop-down or folding attic stair is installed in a garage ceiling, and if so, whether it is a rated assembly or has been covered with the appropriate gypsum board thickness to preserve the required fire separation. Check whether the door between the garage and the house is a solid-core or fire-rated door rather than a hollow interior door. Gather any permit records for a garage conversion or addition, and note the finish quality, heat source, and interior accessibility of the converted space regardless of permit status, since these are the specific factors FHA guidance points to. Confirm the local zoning classification's parking requirements independently of the permit question, since a jurisdiction can treat an unpermitted conversion as a zoning non-conformity even where an appraiser is willing to give some value credit for the space.